Solutions & flagship projects

Humidity control for electronics plants

Electronic components and boards absorb moisture when left in humid air; in the reflow oven the trapped vapour expands and cracks or blisters them (the 'popcorn' defect). Conversely, a room that is too dry builds static. Electronics plants therefore need humidity held stable within a product-specific range in production rooms, component stores and cleanrooms. ENCO supplies HARISON industrial dehumidifiers for production rooms and component stores, DryMax desiccant dehumidifiers when very low humidity is needed, and HUMAX humidifiers when cleanrooms are too dry, and has installed them in electronic-component plants in Hung Yen, Bac Ninh, Hai Phong and Hanoi.

Humidity above the limit makes components absorb moisture, fail at soldering and oxidise their leads; humidity too low causes static that destroys chips. Electronics plants need both dehumidification and humidification depending on season and area.

Technical content byThS. Nguyễn Minh Thái · Updated

What moisture causes

  • Components and boards absorb moisture and crack or blister in the reflow oven
  • Oxidised leads and boards, poor solderability
  • Overly dry rooms build static that damages chips
  • Component stores exceed storage limits in the 'nồm' season

Conditions to hold

According to each product and customer standard. Reference: production rooms and component stores are usually held stable within about 40–60 %RH; especially moisture-sensitive parts are kept in dry cabinets.

Reference values. ENCO engineers calculate to the requirements and actual moisture load of each site.

ENCO's solution

  • Survey each room, measure actual humidity and calculate the moisture load
  • HARISON industrial dehumidifiers (floor-standing, ceiling-mounted) for production rooms and component stores
  • HUMAX humidifiers for cleanrooms when humidity is too low
  • DryMax desiccant dehumidifiers for areas needing very low humidity

By area and process

AreaConditions and risksHow ENCO handles it
Component and material storeHumidity rises in the rainy and 'nồm' seasonsHARISON dehumidifiers; moisture-sensitive parts in dry cabinets
SMT and assembly roomsComponents absorb moisture before reflowHARISON dehumidifiers against the walls with fixed drainage
Cleanrooms and equipment roomsHumidity too low in the dry season, causing staticHUMAX humidifiers controlled by sensors
Areas requiring very low humidityAir-conditioning cannot reach itDryMax desiccant dehumidifier

Typical equipment

Featured projects

See all engineering activities →

Selected ENCO installations

DateProvinceWork
11/2025Hung YenHARISON HD-192B dehumidifiers for an electronic-component production room
11/2025Hung YenHARISON HCD-90 and HCD-150 ceiling dehumidifiers for an electronics equipment room
10/2025Bac NinhHUMAX HMR-20 humidifier for an electronics cleanroom
09/2025Hai PhongHARISON HD-360PS dehumidifiers for an electronic-component warehouse
08/2025Hung YenHARISON HD-504B dehumidifiers for an electronic-component production room
05/2025HanoiHARISON HD-192B dehumidifiers for an electronic-component storage room
04/2025Ho Chi Minh CityHARISON HCD-504B ceiling dehumidifier for a semiconductor-equipment workshop
03/2025Phu ThoHARISON HD-192B and HD-504PS dehumidifiers for an electronics plant

From ENCO service records; customer names are not disclosed.

FAQ

Why do electronic components crack during soldering?

Because the components absorbed moisture while stored in humid air. In the reflow oven the trapped vapour expands suddenly, cracking or delaminating the package. Keeping stores and production rooms at stable humidity and keeping moisture-sensitive parts in dry cabinets limits this defect.

What humidity should an electronics plant keep?

Usually held stable within about 40–60 %RH for production rooms and component stores, but the exact level follows product and customer requirements. Too humid and components absorb moisture; too dry and static builds up.

What if an electronics cleanroom is too dry in the dry season?

Use humidifiers controlled by humidity sensors, such as HUMAX humidifiers, to keep humidity above the minimum and limit static.

What information does ENCO need to quote for an electronics plant?

Dimensions of each room, the humidity required by the product or customer standard, whether there is air-conditioning or a cleanroom, number of doors and how often they open, and current humidity readings if available.

Ask ENCO engineers to design a solution for your site